Setting of Ejection Mode and Count on Injection Molding Machine

Setting of Ejection Mode and Count on Injection Molding Machine

[1] Press [MAN] of the OPERATION
selector button on the operation controller and close the safety gate.
Operation Buttons

[2] Mold opening
Continuously press [OPEN] of the MOLD button to open the mold to the open limit.
Mold open close buttons
[3] Setting of ejection mode and count

(A) With ejector [A] circuit used

This mode starts ejection with the mold located at the open limit. Display the [CLAMP] screen on INJECTVISOR, for setting.
1) Press the [CLAMP] screen selector button and the [CLAMP] screen change button to display the [CLAMP] screen.
2) Touch [A] of the [EJECT MODE] switch to select ejection mode [A].
With ejector [A] circuit used in setting on injection molding machine

3) Touch [EJC COUNTS] on the [CLAMP] screen to open the [EJC COUNTS] setting window.
* When [HOLD] of [EJC COUNTS] is selected, ejectors return automatically on completion of [MID] time.
4) Set the necessary ejection count on the setting window.
5) Touch [x] (close) to close the window.
ejection count on the setting window

(B) With ejector [B] circuit used

This mode starts ejection at the preset “LS30” position during retraction of the movable mold.
Display the [CLAMP] screen on INJECTVISOR, for setting.
[CLAMP] screen on INJECTVISOR for toshiba injection molding machines
1) Press the [CLAMP] screen selector button and the [CLAMP] screen change button to display the [CLAMP] screen.
2) Select ejection mode [B] on the [CLAMP] screen.
3) Touch [EJC COUNTS] on the [CLAMP] screen to open the [EJC COUNTS] setting window.
4) Set the necessary ejection count on the setting window.
5) Touch [x] (close) to close the window.
ejection counting setting window

6)Touch [LS30] on the [CLAMP] screen to open the [LS30 B-MODE POSITION] setting window.
7) Set the position of movable platen possible to start ejection in the step switch on the window.
8) Touch [x] (close) to close the window.

The screen on the next page shows setting procedure.

(C) With ejector [HOLD] circuit used Display the [CLAMP] screen on INJECTVISOR, for setting.

1) Press the [CLAMP] screen selector button and the [CLAMP] screen change button to display the [CLAMP] screen.
2) Touch [A or B] of [EJECT MODE] switch to select ejection mode [A or B].
3) Touch [EJC COUNTS] on the [CLAMP] screen to open the [EJC COUNTS] setting window.
4) Touch [HOLD] on the setting window.
[CLAMP] screen for ejector setting

5) Touch [x] (close) to close the window.
6) Touch [EJECT HOLD] to open the [EJECT HOLD] setting window.
7) Set the ejection hold time in the step switch on the window.
8) Touch [x] (close) to close the window.
ejection hold time setting

NOTE: When ejection mode [B] is selected, set [LS30] (ejection start position).