Manual Charging on Toshiba Injection Molding Machines
MANUAL charging is necessary before carrying out MANUAL operation, SEMI-AUTOMATIC operation and AUTOMATIC operation.
(The following descriptions are given on condition that resin has been supplied and barrel heating up has been completed before starting operation.)
Screw Rotation Speed(SRN) 20min-1
Back Pressure (BP) 49MPa (Max. setting)
* In order to avoid a problem, Back Pressure (BP) here should be high enough for the screw not to retract during its rotation.
Use the operation controller to operate the machine by following the procedure below.
[1] Press [MAN] of the OPERATION selector button.
[2] Close the safety gate. Then press [INJ] of the SCREW button and move the screw to the advance limit.
※The LED blinks during charging.
※After the LED flicker became from slow to fast, charging continues without pressing [CHARGE] button.
※The LED lights after the completion of charging.