How to check Belt Dislocating of All-electric Injection Molding Machines
Follow the procedure below to check timing belt dislocating on respective units (clamp unit, ejection device, injection drive unit, charge drive unit).
1) Move respective drive units on their stroke to [0] mm point.
2) Check if white marks on the pulley and belt meet, both on the drive and driven sides.
By TOSHIBA MACHINE CO.,LTD.