Prohibited Operations on Toshiba Injection Molding Machines
Daily inspection and maintenance are essential to make the injection molding machine operate at its designed potential and to maximize its service life. However, the following operations regarding maintenance and modification of the machine should not be attempted by the user. Please observe these restrictions.
1. Clamp Unit
1) Disassembly and repair of ball screw
2) Replacement of timing belt and pulley
3) Removing and setting of gears on mold thickness setter
2. Injection Unit
1) Disassembly and repair of load cell
2) Disassembly and repair of ball screw
3) Replacement of timing belt and pulley
3. Electric Components
1) Disassembly and repair of servomotor
2) Disassembly and repair of geared motor
3) Disassembly and repair of PC board
4) Modification and addition of electric circuit
4. Frame
1) Welding and drilling onto the frame